OCPRF100 MP Server System Technical Product Specification
Revision 1.0

54

5.

Power Supply

This document defines the requirements for a universal input switching power supply, which pro-
vides 750 watts DC with power factor corrected AC input and with current and remote sense reg-
ulation. The power supply is used with its DC outputs paralleled with other identical supplies to
form a redundant power system with system operating replacement capability (hot-swap). All
power supply connectors, including AC and DC connectors, accommodate “blind mating.” The
supply

has four externally enabled outputs, one +5 V standby output at 1.0 A, and one +15 Vdc

standby output at 200 mA. Both +5 Vdc and +15 Vdc standby outputs are present whenever AC
power is applied.

The four externally enabled outputs have the following ratings:

+3.3 Vdc at 36 A

+5

Vdc at 36 A

+12

Vdc at 36 A

with 42 A peak

-12

Vdc at

1 A

5.1

Mechanical Requirements

5.1.1

Mechanical Outline

The mechanical outline and dimensions are shown in Figure 5-1: Outline Drawing of Power Sup-
ply Enclosure.
The unit of measurement is inches. The following mechanical sketches should be
used for preliminary reference only.

Refer to the Power Supply, 750/650W, PFC, 5 Outputs docu-

ment for a detailed drawing.

Figure 5-1: Outline Drawing of Power Supply Enclosure