Figure 60. RAID Configuration Program - Create/Delete A r r a y M e n u

1. Select Define hot-spare drive. The cursor becomes active in the Bay/Array

selection list.

2. Use the up and down arrow keys to select the RDY (ready) drive to be used

as a hot-spare and press Enter. The RDY status changes to HSP (hot-spare).
Figure 61 shows an example where a hot-spare disk has been defined.

3. Press Esc to validate.

Notes:

1. The hot-spare drive is not associated with any array. If m o r e than one array

is defined, you need only 1 hot-spare drive for all the arrays.

2. If the disks have different sizes, the hot-spare drive must be the largest.

IBM RAID Controller Configuration Ver 2.12

Adapter in Slot 1

┌────────────────────────────┐

┌───────────┐

┌───────────┐

Create/Delete Array

│┌─────────┐│

│┌─────────┐│

├────────────────────────────┤

│└Ch

1┘│

│└Ch

2┘│

│1. Help

│┌─Bay

│┌─Bay

│2. Define hot-spare drive

││ Array ──┐│

││ Array ──┐│

│3. Delete disk array

┌─────┐

┌─────┐

│4. Create disk array

│1 └

│1 └

│5. Define Logical drive

┌─────┐

┌─────┐

│6. Format drive

│2 └

│2 └

│7. Exit

│ ┌─────┐ │ │ ┌─────┐ │

└────────────────────────────┘

│3 └ HSP ┘

│3 └

│ ┌─────┐ │ │ ┌─────┐ │
│4 └ RDY ┘

│4 └

│ ┌─────┐ │ │ ┌─────┐ │
│5 └ RDY ┘

│5 └

│ ┌─────┐ │ │ ┌─────┐ │
│6 └ RDY

│6 └

│ ┌─────┐ │ │ ┌─────┐ │
│7 └

┘ │ │7 └

┘ │

└───────────┘ └───────────┘

Figure 61. RAID Configuration Program - Hot-Spare Disk Definition

Chapter 3. H a r d w a r e Configuration

107

Advertising