IBM SG24-4576-00 User Manual

Page 41

Advertising
background image

┌───────┴───────┐

Disk

Controller

└───────┬───────┘


┌────────────┼────────────┐
│ │ │

┌────┴─────┐ ┌────┴─────┐ ┌────┴─────┐

DATA

AAA

│ │

BBB

│ │

CCC

├──────────┤ ├──────────┤ ├──────────┤

DATA MIRROR

CCC

│ │

AAA

│ │

BBB

├──────────┤ ├──────────┤ ├──────────┤

DATA

DDD

│ │

EEE

│ │

FFF

├──────────┤ ├──────────┤ ├──────────┤

DATA MIRROR

FFF

│ │

DDD

│ │

EEE

└──────────┘ └──────────┘ └──────────┘

Disk 1

Disk 2

Disk 3

Figure 14. RAID-1 Enhanced, Data Strip M i r r o r i n g

Some vendors have also implemented another slight variation of RAID-1 and
refer to it as RAID-10 since it combines features of RAID-1 and RAID-0. Others
refer to this technique as RAID-6, which is the next available RAID level.

As shown in Figure 15, this solution consists of mirroring a striped (RAID-0)
configuration. In this example, a RAID-0 configuration consisting of 2 drives
(drive 1 and 2) is mirrored to drives 3 and 4.

┌───────┴───────┐

Disk

Controller

└───────┬───────┘


┌────────────┬──────┴─────┬────────────┐
│ │ │ │

┌────┴─────┐ ┌────┴─────┐ ┌────┴─────┐ ┌────┴─────┐

AAA

│ │

BBB

│ │

AAA

│ │

BBB

├──────────┤ ├──────────┤ ├──────────┤ ├──────────┤

CCC

│ │

DDD

│ │

CCC

│ │

DDD

├──────────┤ ├──────────┤ ├──────────┤ ├──────────┤

EEE

│ │

FFF

│ │

EEE

│ │

FFF

├──────────┤ ├──────────┤ ├──────────┤ ├──────────┤

GGG

│ │

HHH

│ │

GGG

│ │

HHH

└──────────┘ └──────────┘ └──────────┘ └──────────┘

Disk 1

Disk 2

Disk 3

Disk 4

Figure 15. RAID-6,10 - M i r r o r i n g of RAID 0 Drives

Performance and capacity are similar to RAID 1. 50% of total disk capacity is
usable. However, this solution always uses an

even number of disks. RAID-1

enhanced can use an

odd number of disks. RAID-1 also can be mixed with

others RAID levels.