The following lines need to be added to AUTOEXEC.NCF:
SEARCH ADD SYS:NETFIN\
LOAD NETFBASE
If you choose to update AUTOEXEC.NCF,
AUTOEXEC.NCF will be backed up to AUTOEXEC.RPS.
Otherwise, additions will be saved to the file
AUTOEXEC.NEW in the path SYS:NETFIN\.
Update AUTOEXEC.NCF(Enter Y or N)?

SYS:NETFIN\ is the default target path or the new path you entered during
the installation procedure.

17. Type

Y

if you want NetFinity Services for NetWare to start automatically when

the server is started. Press Enter.

18. Press any key to close the screen.

The NetFinity Services for NetWare installation is now complete.

19. Type

DOWN

at the colon prompt.

20. Type

EXIT

at the colon prompt to return to DOS.

21. Reboot the server to start NetFinity Services for NetWare.

4.6.2.2 Installing with Diskettes from a Workstation

To install NetFinity Services for NetWare from a workstation, the workstation
must have NetFinity Manager for OS/2, NetFinity Services for OS/2, or NetFinity
Services for Windows installed.

To install NetFinity Services for NetWare from a workstation:

1. Log on to the NetWare server from the workstation.

2. Map a drive letter to a directory on the server where NetFinity Services for

NetWare will be installed.

3. Insert NetFinity Services for NetWare Diskette #1 into diskette drive.

4. Start the NetFinity installation program.

If the workstation is running OS/2:

a. Start an OS/2 full screen or OS/2 windows session.
b. Type

A:INSTALL

and then press Enter.

If the workstation is running windows:

a. Select File from the program manager menu bar.
b. Select Run... from the File pull-down menu.

c. Type

A:NETFINS

in the command line field and then select OK.

A window like the one in Figure 107 will appear.

Figure 107. NetFinity Installation

Chapter 4. Novell NetWare Installation

147