J. T. Eaton Liquid-Cooled Drives LCX9000 User Manual

Page 48

Advertising
background image

LCX9000 Liquid-Cooled Drives User Manual

3-2

For more information visit: www.EatonElectrical.com

MN04005001E

January 2007

Table 3-1: Cable Types Required to Meet Standards

Cable Data

Table 3-2: Cable Sizes 400 – 500V

Number of bolt connections = 2.

Number of bolt connections = 4.

See Main Terminal Cable Size.

Cable Type

Level N/T

Mains Cable

Power cable intended for fixed installation and the specific mains voltage.
Shielded cable not required.

Motor Cable

Power cable intended for fixed installation and the specific mains voltage.
Shielded cable not required.

Control Cable

Screened cable equipped with compact low-impedance shield.

Chassis

Catalog
Number

I

th

Mains and
Motor Cable
Cu (mm

2

)

Terminal Cable Size

Max. Number of
Cables/Bolt Size

Main Terminal
(mm

2

), Max.

Ground Terminal
(mm

2

)

CH3

LCX016A0-4

16

3x2.5+2.5

50

1 – 10

LCX022A0-4

22

3x4+4

50

1 – 10

LCX031A0-4

31

3x6+6

50

1 – 10

LCX038A0-4
LCX045A0-4

38 – 45 3x10+10

50 Cu
50 Al

6 – 35

LCX061A0-4

61

3x16+16

50 Cu
50 Al

6 – 35

CH4

LCX072A0-4

72

3x25+16

50 Cu
50 Al

6 – 70

1/M8

LCX087A0-4

87

3x35+16

50 Cu
50 Al

6 – 70

1/M8

LCX105A0-4

105

3x50+25

50 Cu
50 Al

6 – 70

1/M8

LCX140A0-4

140

3x70+35

95 Cu/Al

25 – 95

1/M8

CH5

LCX168A0-4

168

3x95+50

185 Cu/Al

25 – 95

2/M10

LCX205A0-4

205

3x150+70

185 Cu/Al

25 – 95

2/M10

LCX261A0-4

261

3x185+95 or
2x(3x120+70)

185 Cu/Al 2

25 – 95

2/M10

CH61

LCX300A0-4

300

3x240+120

25 – 185

2/M12

LCX385A0-4

385

2x(3x120+70)

25 – 185

2/M12

CH62/72 LCX460A0-4

460

2x(3x150+70)

25 – 185

4/M12

LCX520A0-4

520

2x(3x185+95)

25 – 185

4/M12

LCX590A0-4
LCX650A0-4

590
650

3x(3x150+70)

25 – 185

4/M12

LCX730A0-4

730

3x(3x150+70)

25 – 185

4/M12

Advertising