Lcx9000 liquid-cooled drives user manual – J. T. Eaton Liquid-Cooled Drives LCX9000 User Manual

Page 67

Advertising
background image

LCX9000 Liquid-Cooled Drives User Manual

MN04005001E

For more information visit: www.EatonElectrical.com

4-9

January 2007

Figure 4-12: Jumper Selection for OPT-A9

Note: If you change the AI signal content also remember to change the corresponding board

parameter in menu M7.

Jumper Block X1:

AI1 Mode

AI1 Mode: 0...20mA; Current Input

A B C D

A B C D

A B C D

AI1 Mode: Voltage Input; 0...10V

AI1 Mode: Voltage Input; 0...10V (Differential)

AI1 Mode: Voltage Input; -10...10V

A B C D

Jumper Block X6:

AO1 Mode

AI1 Mode: 0...20mA; Current Output

A B C D

A B C D

AO1 Mode: Voltage Output; 0...10V

= Factory Default

Jumper Block X2:

AI2 Mode

AI2 Mode: 0...20mA; Current Input

A B C D

A B C D

A B C D

AI2 Mode: Voltage Input; 0...10V

AI2 Mode: Voltage Input; 0...10V (Differential)

AI2 Mode: Voltage Input; -10...10V

CMB Connected to GND

A B C D

Jumper Block X3:

CMA and CMB Grounding

CMA Connected to GND

CMB Isolated from GND

CMA Isolated from GND

CMB and CMA
Internally Connected Together,
Isolated from GND

Advertising