J. T. Eaton Liquid-Cooled Drives LCX9000 User Manual

Page 96

Advertising
background image

LCX9000 Liquid-Cooled Drives User Manual

5-20

For more information visit: www.EatonElectrical.com

MN04005001E

January 2007

Parameter Comparison

In the Parameter Comparison submenu (S6.4), you can compare the actual parameter values
to the values of your customized parameter sets and those loaded to the control keypad.

You can compare the parameter by pressing Menu Button Right in the Compare Parameters
submenu. The actual parameter values are first compared to those of the customized
parameter Set1. If no differences are detected, “0” is displayed on the lowermost line. If any
of the parameter values differ from those of Set1, the number of the deviations is displayed
together with symbol P (for example, P1

➔P5 = five deviating values). By pressing Menu

Button Right once more, you can enter pages where you can see both the actual value and
the value it was compared to. In this display, the value on the description line (in the middle)
is the default value and the one on the value line (lowermost) is the edited value.
Furthermore, you can also edit the actual value with the Browser buttons in the edit mode
which you can enter by pressing Menu Button Right once.

In the same way, you can perform the comparison of the actual values to Set2, Factory
Settings and Keypad Set.

Figure 5-15: Parameter Comparison

Set1

Or

0

56.4.1

Set1

56.4.1

P2.1.2= 50.0

56.4.1.1

ParamComparison

56.4

Confirm Change

Edit Value

C1

C3

P1

P6

P2.1.2= 50.0

56.4.1.1

20.0 Hz

20.0 Hz

Advertising