Drive Status Indicators

The drive status symbols tell the user the status of the motor and the drive. In addition, they
tell about possible irregularities detected by the motor control software in motor or drive
functions.

Table 5-1: Drive Status Indicators

Control Place Indicators

The symbols I/O term, Keypad and Bus/Comm (see Table 5-2) indicate the choice of control
place made in the Keypad control menu (M3) (see Page 5-9).

Table 5-2: Control Place Indicators

Indicator

Description

RUN
Motor is running; Blinks when the stop command has been given but the
frequency is still ramping down.

Indicates the direction of motor rotation.

STOP
Indicates that the drive is not running.

READY
Lights up when AC power is on. In case of a trip, the symbol will not light up.

ALARM
Indicates that the drive is running outside a certain limit and a warning is
given.

FAULT
Indicates that unsafe operating conditions were encountered due to which
the drive was stopped.

Indicator

Description

I/O Terminal
I/O terminals are selected as the control place i.e. START/STOP commands or
reference values etc. are given through the I/O terminals.

Keypad
Control keypad is selected as the control place i.e. the motor can be started or
stopped, or its reference values etc. altered from the keypad.

Bus/Comm
The drive is controlled through a fieldbus.