The manual – Siemens sitrans LU01 User Manual

Page 10

Advertising
background image

Page 4

SITRANS LU01 – INSTRUCTION MANUAL

7ML19985BE02

mmmmm

Int

rod

uct

io

n

•

Material:

Liquid or solid; automatically adjusts echo processing with one
entry.

•

Response:

Slow, medium, fast, surge, or immediate response to material
level changes.

•

Units:

Display Readings in m, cm, mm, ft, in, %, or any other units
desired.

• Volume:

8 pre-programmed tank shape options. 2 universal tank shape
programming methods

• Failsafe:

Failsafe options for process control equipment activation.

• Relays:

8 functions including level, rate of change, pump control,
temperature and more.
Fixed or independent on/off setpoints

• mA Outputs:

Based on level, space, distance, or volume.There are 4 range
selections: 0-20, 4-20, 20-0, or 20-4 mA with an adjustable
range and over-range limits

The Manual

The manual is designed to help you get the most out of your SITRANS LU01, and it
provides information on the following:

If you have any questions, comments, or suggestions about the manual contents, please
e-mail us at [email protected].

For the complete library of Siemens Milltronics manuals, go to
www.siemens.com/processautomation

•

Product specifications

•

Outline diagrams

•

Wiring diagrams

•

Installation and interconnection
requirements

•

How to program the unit

•

Principles of operation

•

Parameter values

•

Technical Reference

•

Example applications

•

Troubleshooting guide

•

Programming chart

REMEMBER!

Fill out Programming chart on page 104 or record parameters using Dolphin Plus.