(20mm) integrated in the mecablitz must not
be swivelled in front of the reflector. ADI flash
control or the preflash function must be deac-
tivated if any of the aforementioned attach-
ments are to be used. For this purpose it will
be sufficient to switch the mecablitz from TTL-
HSS mode to TTL mode (see Section 4.13.2 or
refer to the camera’s operating instructions).

4.19.2 Dimage A1, A2, 5, 7, 7i, 7Hi

For system-induced reasons ADI flash control with
the above digital cameras can be performed in
conjunction with the following flash units: meca-
blitz 32 Z-2, 32 MZ-3, 40 MZ-1, 1i, 3, 3i, 45 CL-4
(with SCA 3000C), 50 MZ-5, 54 MZ-..., 70 MZ-..
and 76 MZ-5 digi.

For ADI flash control the mecablitz must be set to
TTL mode.

If an attachment is mounted in front of the
reflector or when bouncing the flash, it is
advisable to use TTL pre-flash metering
instead of the ADI flash control (see 4.18). For
further information please refer to the came-
ra’s operating instructions.

mecablitz 32 Z-2, 32 MZ-3, 40 MZ-..., 44 MZ-2,
45 CL-4, 50 MZ-3:

This flash mode is not specifically indicated on the
mecablitz or the SCA adapter.

4.20 Wake-up function for the mecablitz

The mecablitz 44MZ-2 and 54MZ-... are fitted with
a facility to automatically switch off the flash unit
1, 3 or 10 minutes after the last flash was fired or

49