2. Mounting the adapter

Before mounting or dismounting the standard
foot 301 or SCA adapter, switch off the meca-
blitz by its main switch and switch off the
camera.

on the mecablitz 32 Z-2, 32 MZ-3, 40 MZ-... ,
50 MZ-5, 70 MZ-... and 76 MZ-5 digi:

• Turn the flash unit’s foot by 90° (not on the

50 MZ-5; 70 MZ-..., 76 MZ-5 digi).

• Press the retention catch against the casing,

simultaneously pushing the hitherto used stand-
ard foot or SCA adapter out of the guide.

Any cover plate that may still be in place (required
for the 301 standard foot or SCA 300 adapter)
should be gripped in the centre and withdrawn.

on the mecablitz 54 MZ-... :

• Open the battery compartment cover.

• Press the coloured unlatching button in the bat-

tery compartment, simultaneously pulling off the
standard foot or SCA adapter.

Any cover plate that may still be in place (required
for the 301 standard foot or SCA 300 adapter)
should be gripped in the centre and withdrawn.

on mecablitz 44 MZ-2:

• Press the locking lever in the middle of the

mecablitz back upwards, keep depressed (if an
SCA adapter from the SCA 3002 system is
being used then the flap on the back of the
adapter must first be opened) and simulta-
neously withdraw the SCA adapter or 301 stan-
dard foot towards the rear.