Example — Unspecified Connection from a PC Application
120
Commissioning PC Stations - Manual and Quick Start
Release 5/2005
C79000-G8976-C156-07
Activity
3.
You can select the partner, however, only if it already exists in the project.
In this example, you configure an unspecified connection.
In the case of an S7 connection, no project engineering data whatsoever is required on the
partner. In the connection partner for station field, select “(unspecified)”. In the connection for
type field, select “S7 connection”.
To be able to establish the connection, the partner station must be specified by the network
address and access point of the partner application (slot).
Confirm with OK.