Getting Started “Configured Mode”

40

Commissioning PC Stations - Manual and Quick Start

Release 5/2005

C79000-G8976-C156-07

How to Make the Initial Configuration without an XDB File

4

In the properties dialog that opens, give the module an address.

In some cases, you can also set further module parameters, for example bus parameters,
(mandatory with PROFIBUS).

5

Repeat the steps for all other modules that exist in the local station and that you want to
operate in configured mode.

6

Using the “Add” button, add the applications to be operated on the station.

7

Repeat the steps for all other applications you want to use for the configured mode.

Result:

PC station is configured with modules and applications and ready
to receive project engineering data (select online mode)

Tip:

You will also find this procedure in our example “OPC Configuration for
PROFIBUS”; see Section 8.

Where to we go from here?

In the next step, you supply the PC station with project engineering data.