Signal format settings (format), Selecting the start up state (start up) – Sony DVS-9000 User Manual

Page 124

Advertising
background image

Chapter 1

D

V

S-9000 Functions

C:\WINNT\Profiles\Administrator\Desktop\WORK_08_21\370467401
DVS9000WW\01GB03C01-WW.fm

masterpage:Left

124

Setup

DVS-9000/9000SF

3-704-674-01 (1)

Operating mode setting

Single Proc mode: The control panel controls a single switcher.
Dual Simul mode: The control panel controls two switchers.

Device hierarchical relationship setting

Panel Assign: Specify the switcher controlled by a control panel.
Switcher Assign: Specify the DME connected to a switcher.

Signal format settings (Format)

Make the following settings.

Signal format

Specify the signal format to be handled by the devices.
The combinations of signal formats that can be selected are as follows.

Screen aspect ratio

Switch the screen aspect ratio to 4:3 or 16:9.

Selecting the start up state (Start Up)

Set the initial state of the devices when the system is powered on.
For each device, you can select Resume mode or Custom mode.

Resume mode

This resumes the setting state at the previous power-off operation. This setting
is only available for the switcher processor and panel.

Custom mode

This uses the settings saved in non-volatile memory or ROM within the device.
In this mode, there are Setup and Initial Status settings which can be set
separately.
Setup mode: Select the setup state to be used after powering on from the

following.

User: Start up using the user data previously saved with [Setup Define].
Factory: Start up with the factory default settings.

Initial status mode: Select the state of each device after powering on

(excluding the settings to which “setup” applies).

User: Start up using the user data previously saved with [Initial Status

Define].

Factory: Start up with the factory default settings.

Field frequency

Effective number of scan lines

59.94

480i

50

576i