Dme setup, Setup relating to dcu input/output – Sony DVS-9000 User Manual

Page 131

Advertising
background image

131

C:\WINNT\Profiles\Administrator\Desktop\WORK_08_21\370467401
DVS9000WW\01GB03C01-WW.fm

masterpage:Right

Setup

Chapter 1

D

V

S-9000 Functions

DVS-9000/9000SF

3-704-674-01 (1)

Link settings (Link)

Internal Bus Link: Make a setting of the bus link function that links

together two buses internal to the switcher.

GPI Output Button Link: Make settings for linking any cross-point buttons

or [CUT] and [AUTO TRANS] buttons in the cross-point control block and
GPI output ports.

External device connections (Device Interface)

GPI Input: Set the GPI input ports and trigger polarities, and make the

action settings.

GPI Output: Set the GPI output ports and trigger polarities, and make the

action settings.

DME Setup

In DME setup, carry out settings particular to the DME processor.
You can make the following settings.

Input signal settings (Input)

Initial Crop: Make the initial crop setting for each button number in the

cross-point assign main table.

Matte Illeg. Color Limit: Switch the illegal limiter for the signal generated

by the DME internal matte generator on or off.

Interface with external devices (Device Interface)

Editor Protocol: Set the protocol to be used on the Editor Port.
GPI Input: Various settings for GPI Input 1 to 8 Ports.
GPI Output: Various settings for GPI Output 1 to 8 Ports.

Setup Relating to DCU Input/Output

In DCU setup, carry out settings particular to the DCU.
You can make the following settings.
Input Config: Assign GPI inputs to Parallel input ports.
GPI Input Assign: Make GPI input settings.
Output Config: Assign GPI outputs to parallel output ports inserted in an

option slot.

GPI Output Assign: Make GPI output settings.

Advertising