KORG Electronic Keyboard User Manual

Page 124

Advertising
background image

Program mode: HD-1

114

Note Map Table

[+0000…+0064]

Assigns the “Table (Note Map Table)” (Program 7–3b)
function.

+0000: Custom

+0001…+0064: Global Tables 1…64

For more information, see “Table (Note Map Table)” on
page 106.

Note Map Transpose

[–0012…+0012]

Assigns the ”Transpose (Note Map Transpose)”
(Program 7-3b) function.

For more information, see “Transpose (Note Map
Transpose)” on page 106.

Note Map Chord Track

[+0000, +0001]

Assigns the “Chord Track (Note Map Chord Track)”
(Program 7–3b) function.

+0000: Off

+0001: On

For more information, see “Chord Track (Note Map
Chord Track)” on page 107.

Note Map Kbd Track

[+0000, +0001]

Assigns the “Keyboard Track (Note Map Kbd Track)”
(Program 7–3b) function.

+0000: Off

+0001: On

For more information, see “Keyboard Track (C2 Ref)
(Note Map Kbd Track)” on page 107.

Group: Trigger

Quantize Trigger

[+0000, +0001]

Assigns the “Quantize Trigger” (Program 7–4b)
function.

+0000: Off

+0001: On

For more information, see “Quantize Trigger” on
page 108.

Update On Release

[+0000, +0001]

Assigns the “Update On Release” (Program 7–4b)
function.

+0000: Off

+0001: On

For more information, see “Update On Release” on
page 108.

Delay Start

[+0000…+0025]

Assigns the “Delay Start” (Program 7–4b) function.

+0000: Off

+0001: Fixed

+0002…+0025:

3…4x

For more information, see “Delay Start” on page 108.

Delay Start ms

[+0000…+5000]

Assigns the “Delay Start Fixed” (Program 7–4b)
function.

See “Delay Start Fixed”

☞p.108

Note Trigger

[+0000…+0003]

Assigns the “Note Trigger” (Program 7–4b) function.

+0000: Any

+0001: AKR

+0002: 1st

+0003: Dyn

For more information, see “Note Trigger” on page 109.

Note Latch

[+0000, +0001]

Assigns the “Note Latch” (Program 7–4b) function.

+0000: Off

+0001: On

For more information, see “Note Latch” on page 109.

Env1 Trigger

[+0000…+0003]

Env2 Trigger

[+0000…+0003]

Env3 Trigger

[+0000…+0003]

Assigns the Envelope “Trigger” (Program 7–4b)
functions.

+0000: Any

+0001: AKR

+0002: 1st

+0003: Dyn

For more information, see “Envelope Trigger” on
page 109.

Env1 Latch Mode

[+0000…+0004]

Env2 Latch Mode

[+0000…+0004]

Env3 Latch Mode

[+0000…+0004]

Assigns the “Latch” (Program 7–4b) function.

+0000: Off

+0001: Sus1

+0002: Rel1

+0003: Sus2

+0004: Rel2

For more information, see “Envelope Latch” on
page 109.

Group: ZoneThru Inside Zone

[+0000, +0001]

Assigns the “Thru In Zone” (Program 7–1a) function.

+0000: Off

+0001: On

For more information, see “Thru In Zone” on page 99.

Thru Outside Zone

[+0000, +0001]

Assigns the “Thru Out Zone” (Program 7–1a) function.

+0000: Off

+0001: On

For more information, see “Thru Out Zone” on
page 99.

Advertising