Loading Media 13

C. LABEL SENSOR CALIBRATION

After the ribbon and labels are loaded, it is necessary to

perform a quick calibration procedure for the label sensor.
1. Turn off the printer. Press and hold the PAUSE button.
2. Turn on the power.
3. When the printer is in calibration mode, both the READY

and the MEDIA LED indicators will blink. At this point

release the button.

4. The printer will feed the labels for 12 inches.
5. When the READY and MEDIA LED indicators stop

blinking and remain illuminated, the calibration is

complete and the labels should feed properly between

gaps.

Note: This procedure is very important to perform upon initial installation

and every time thereafter that the media type is changed. Failure to

do so will result in the gap and label-empty detection being incorrect.

D. PERFORMING A SELF TEST

Before sending data to the printer, you may want to perform a

Self Test to confirm that the printer itself is working properly.
1. Turn off the printer. Press and hold the FEED button.
2. Turn on the power.
3. The READY LED indicator will blink for few seconds.
4. The printer will print out a configuration report.
5. The READY LED indicator will stop blinking and stays lit.
6. The following information will be printed on this report.

-

Font list

-

Hardware configuration and status

-

Label parameters

-

Firmware version

510172_r1.qxd 3/21/2001 6:25 PM Page 13