Primera Technology Cyclone C-1000 User Manual
Page 30

26Command Language Quick Reference
(Table continued from previous page)
Command
Description
Parameter
Factory default
<STX>KI<m
Set symbol set
m: 0 - USASCII, 0 for USASCII
for ASD smooth
1 - United
font set
Kingdom,
2 - Spanish,
3 - Swedish,
4 - French,
5 - German,
6 - Italian,
7 - Danish/
Norwegian.
Interaction Commands
These commands only apply to the serial port and allow the
host to understand the status and configuration of the printer.
Command
Description
Response
Contents
<SOH>#
Reset
Y
<XOFF><XON>T
<SOH>A
Send a readable
Y
<8 bytes, Y/N> <CR>
status string
byte 1 : Y - printer busy
byte 2 : Y - paper out
byte 3 : Y - ribbon out
byte 4 : N (always)
byte 5 : Y - printing
byte 6 : Y - printer
paused
byte 7 : Y - label
presented
byte 8 : N (always)
<SOH>B
Toggle pause
N
condition
<SOH>E
Send the
Y
e. g.
number of
0000<CR>
labels to be
no label left to be
printed
printed
<SOH>F
Send status byte
Y
n<CR>
same as <SOH>A,
except bit 1 ~ 8 are
corresponding to byte
1 ~ 8 of <SOH>A.
510172_r1.qxd 3/21/2001 6:25 PM Page 26