Raid – Network Instruments GigaStor 114ff User Manual

Page 114

Advertising
background image

What is a probe instance?
Chapter 8 Probe Instances

114

rev. 1

N

OTE

:

By default there is one active probe instance for GigaStor. It
binds to the network adapter and its ports. If you have a
specific need to separate the adapter’s ports and monitor
them separately, you can do so through passive probe
instances or you can create separate virtual adapters. See
“Configuring virtual adapters on the Gen2 card” on page 116.

Figure 76 shows how one active probe instance captures and writes to
the GigaStor RAID. Passive probe instances 1 and 2 mine data from
the RAID array. As a best practice the passive probe instances are
bound to the slowest network adapter in the GigaStor.

Additionally, passive probe instance 3 and 4 each are capturing
packets separate from each other and separate from the active probe
instance. However, since they are also bound to the same adapter as
the active probe instance, they are capturing the same data as the
active probe instance.

Figure 76 GigaStor capture and packet capture through probe instances

Active

Instance

Passive

Instance

1

Passive

Instance

4

RAID

RAM

m

inin

g

Passive

Instance

2

Passive

Instance

3

RAM

m

in

in

g

DTE

DCE

DCE

1

2

DTE

Virtual

Adapter

GigaStor capture

1

2

3

4

Slowest

Adapter

packet

captur

e

packet

captur

e

Advertising