Board configuration, Analog i/o configuration, Table 21. analog i/o settings – National Instruments PCI-1200 User Manual

Page 19: Board configuration -2, Analog i/o configuration -2, Table 2-1, Analog i/o settings -2

Advertising
background image

Chapter 2

Installation and Configuration

PCI-1200 User Manual

2-2

© National Instruments Corporation

Board Configuration

The PCI-1200 is completely software configurable. The PCI-1200 is fully
compliant with the PCI Local Bus Specification, Revision 2.0. Therefore,
all board resources are automatically allocated by the system. For the
PCI-1200, this allocation includes the base memory address and interrupt
level. You do not need to perform any configuration steps after the system
powers up.

Analog I/O Configuration

Upon power-up or after a software reset, the PCI-1200 is set to the
following configuration:

Referenced single-ended input mode

±5 V analog input range (bipolar)

±5 V analog output range (bipolar)

Table 2-1 lists all the available analog I/O configurations for the PCI-1200
and shows the configuration in reset condition.

Both the analog input and analog output circuitries are software
configurable. Refer to your software documentation for more information
on changing these settings.

Table 2-1. Analog I/O Settings

Parameter

Configuration

Analog Output CH0 Polarity

Bipolar—±5 V (reset condition)
Unipolar—0 to 10 V

Analog Output CH1 Polarity

Bipolar—±5 V (reset condition)
Unipolar—0 to 10 V

Analog Input Polarity

Bipolar—±5 V (reset condition)
Unipolar—0 to 10 V

Analog Input Mode

Referenced single-ended (RSE) (reset condition)
Nonreferenced single-ended (NRSE)
Differential (DIFF)

Advertising