Timing specifications, Table 3-6. signal names used in timing diagrams, Timing specifications -27 – National Instruments PCI-1200 User Manual
Page 49: Table 3-6, Signal names used in timing diagrams -27

Chapter 3
Signal Connections
© National Instruments Corporation
3-27
Timing Specifications
Use the handshaking lines STB* and IBF to synchronize input transfers.
Use the handshaking lines OBF* and ACK* to synchronize output
transfers.
The following signals are used in the mode timing diagrams:
Table 3-6. Signal Names Used in Timing Diagrams
Name
Type
Description
STB*
Input
Strobe Input—A low signal on this handshaking line loads data into the
input latch.
IBF
Output
Input Buffer Full—A high signal on this handshaking line indicates that
data has been loaded into the input latch. This is primarily an input
acknowledge signal.
ACK*
Input
Acknowledge Input—A low signal on this handshaking line indicates
that the data written from the specified port has been accepted. This
signal is primarily a response from the external device that it has
received the data from the PCI-1200.
OBF*
Output
Output Buffer Full—A low signal on this handshaking line indicates
that data has been written from the specified port.
INTR
Output
Interrupt Request—This signal becomes high when the 82C55A is
requesting service during a data transfer. Set the appropriate interrupt
enable signals to generate this signal.
RD*
Internal
Read Signal—This signal is the read signal generated from the PCI
interface circuitry.
WRT*
Internal
Write Signal—This signal is the write signal generated from the PCI
interface circuitry.
DATA
Bidirectional
Data Lines at the Specified Port—This signal indicates when the data
on the data lines at a specified port is or should be available.