Transfer characteristics, Amplifier characteristics – National Instruments PCI-1200 User Manual

Page 70

Advertising
background image

Appendix A

Specifications

PCI-1200 User Manual

A-2

© National Instruments Corporation

Max working voltage..............................In DIFF or NRSE
(signal + common mode) ........................mode, the negative

input/AISENSE should remain
within ±5 V of AGND (bipolar),
or –5 to 2 V (unipolar). The
positive input should remain
within the –5 to +10 V range.

Overvoltage protection ...........................±35 V powered on,

±25 V powered off

Inputs protected ...............................ACH<0..7>

FIFO buffer size......................................4,096 samples

Data transfers ..........................................DMA, interrupts,

programmed I/O

DMA mode .............................................Scatter gather

Dither ......................................................Available

Transfer Characteristics

Relative accuracy....................................±0.5 LSB typ dithered,

±1.5 LSB max undithered

DNL ........................................................±1 LSB max

No missing codes....................................12 bits, guaranteed

Offset error

Pregain error after calibration..........10 µV max

Pregain error before calibration.......±20 mV max

Postgain error after calibration ........1 mV max

Postgain error before calibration .....±200 mV max

Gain error (relative to calibration reference)

After calibration...............................0.02% of reading max

Before calibration ............................±2% of reading max

Amplifier Characteristics

Input impedance

Normal powered on .........................100 G

Ω in parallel with 50 pF

Advertising