Digital trigger, Bus interface, Power requirement – National Instruments PCI-1200 User Manual

Page 77: Physical, Environment

Advertising
background image

Appendix A

Specifications

© National Instruments Corporation

A-9

PCI-1200 User Manual

Protection ............................................... –0.5 to 5.5 V powered on,

±0.5 V powered off

Data transfer ........................................... Interrupts, programmed I/O

Digital Trigger

Compatibility ......................................... TTL

Response ................................................ Rising edge

Pulse width ............................................. 50 ns min

Bus Interface

Type ....................................................... Slave

Power Requirement

Power consumption................................ 425 mA at ±5 VDC (±5%)

Power available at I/O connector ........... +4.65 to +5.25 V fused at 1 A

Physical

Dimensions............................................. 17.45 by 10.56 cm

(6.87 by 4.16 in.)

I/O connector.......................................... 50-pin male

Environment

Operating temperature............................ 0

° to 50° C

Storage temperature ............................... –55

° to 150° C

Relative humidity ................................... 5% to 90% noncondensing

Output low voltage
(I

OUT

= 2.1 mA)

0.45 V

Output high voltage
(I

OUT

= -0.92 mA)

3.7 V

Level

Min

Max

Advertising