Installation, Mantel clearances, Mantel leg clearances – Regency P33 SunriseTM P33S-LP4 User Manual

Page 10: Inst alla tion

Advertising
background image

Regency P33 Sunrise

TM

Gas Fireplace

10

INST

ALLA

TION

INSTALLATION

MANTEL CLEARANCES

Note: Ensure the paint that is used on the mantel

and the facing is "heat resistant" or the
paint may discolour.

MANTEL LEG CLEARANCES

Combustible mantel leg clearances from side of unit
as per diagram:

Drywall

Mantel Clearances

2

0

12

6

4

8

10

2

0

12

6

4

8

10

Top of
Unit

12" (305mm)

0” - 3-1/2" (89mm)

7-1/2"(191mm)

11"(279mm)

7"(178mm)

9"(229mm)

41"(1041mm)

to floor

or 29”(737mm)

to base of unit

3"(76mm)

Standof

f

Side View

Due to the extreme heat this fi replace emits, the
mantel clearances are critical.
Combustible mantel
clearances from top of front facing are shown in the
diagram on the right.

Note: A non-combustible mantel may be

installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.