Installation, Mantel clearances, Mantel leg clearances – Regency P33 SunriseTM P33S-LP4 User Manual
Page 10: Inst alla tion

Regency P33 Sunrise
TM
Gas Fireplace
10
INST
ALLA
TION
INSTALLATION
MANTEL CLEARANCES
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the
paint may discolour.
MANTEL LEG CLEARANCES
Combustible mantel leg clearances from side of unit
as per diagram:
Drywall
Mantel Clearances
2
0
12
6
4
8
10
2
0
12
6
4
8
10
Top of
Unit
12" (305mm)
0” - 3-1/2" (89mm)
7-1/2"(191mm)
11"(279mm)
7"(178mm)
9"(229mm)
41"(1041mm)
to floor
or 29”(737mm)
to base of unit
3"(76mm)
Standof
f
Side View
Due to the extreme heat this fi replace emits, the
mantel clearances are critical. Combustible mantel
clearances from top of front facing are shown in the
diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.