Installation, Inst alla tion – Regency P33 SunriseTM P33S-LP4 User Manual

Page 23

Advertising
background image

Regency P33 Sunrise

TM

Gas Fireplace

23

INST

ALLA

TION

INSTALLATION

Horizontal Venting with Two (2) 90

o

Elbows

Horizontal Venting with Three (3) 90

o

Elbows

One 90

o

elbow = Two 45

o

elbows.

Option

V

H + H1

With these options, maximum
total pipe length is 30 feet
with minimum of 6 feet total
vertical and maximum 8 feet
total horizontal.

Please note minimum 1
foot between 90

o

elbows is

required.

A)

1' Min.

3' Max.

B)

2' Min.

4' Max.

C)

3' Min.

5' Max.

D)

4' Min.

6' Max.

E)

5' Min.

7' Max.

F)

6' Min.

8' Max.

One 90

o

elbow = Two 45

o

elbows.

Option

H

V

H + H1 + H2

With these options,

maximum total pipe

length is 30 feet with

minimum of 11 feet

total vertical and

maximum 9 feet total

horizontal.

P l e a s e n o t e

minimum 1 foot

between 90

o

elbows

is required.

A)

1' Max.

1' Min.

3' Max.

B)

2' Max.

3' Min.

5' Max.

C)

3' Max.

5' Min.

6' Max.

D)

4' Max.

7' Min.

7' Max.

E)

5' Max.

9' Min.

8' Max.

F)

6' Max.

11' Min.

9' Max.

Horizontal Venting with Two (2) 90

o

Elbows

One 90

o

elbow = Two 45

o

elbows.

Option

H

V

H + H1

With these options,

maximum total pipe

length is 30 feet with

minimum of 8 feet total

vertical and maximum 8

feet total horizontal.

Please note minimum

1 foot between 90

o

elbows is required.

A)

1' Max.

1' Min.

3' Max.

B)

2' Max.

2' Min.

5' Max.

C)

3' Max.

4' Min.

6' Max.

D)

4' Max.

6' Min.

7' Max.

E)

5' Max.

8' Min.

8' Max.