Installation, Locating your gas fireplace, Installation checklist – Regency P33 SunriseTM P33S-LP4 User Manual

Page 8: Inst alla tion

Advertising
background image

Regency P33 Sunrise

TM

Gas Fireplace

8

INST

ALLA

TION

INSTALLATION

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label), after burning
appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.

LOCATING YOUR

GAS FIREPLACE

A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner

Diagram 1

1) When selecting a location for your fi replace,

ensure that the clearances are met.

2) The appliance must be installed on a fl at,

solid, continuous surface For example a
wood, metal or concrete fl oor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.

3) The P33 Sunrise™ Gas Fireplace can be

installed in a recessed position or framed
out into the room as in A, B, C and D. See
Diagram 1.

7) Test Gas Pressure (Refer to "Gas Pipe Pres-

sure Testing" section).

8) Install 1 AA battery in the DC Sparker
(see P 31.)

9) Install standard and optional features. Refer

to the following sections:

a)

Optional Stainless Steel Refl ective

Panels

b)

Glass Crystals or Optional Ceramic

Stones

c)

Optional Firebox Base Pebbles

d)

Remote Control or Wall Thermostat

e) Optional

Fan

Assembly

f) Faceplate


10) Wall Mounted ON/OFF Switch:

Use the toggle wall switch supplied with the
manual package. Use of a “decor” switch
causes higher resistance which is a problem
on gas fi replaces.

11) Final check.

INSTALLATION

CHECKLIST

1) Locate appliance

a) Room location (Refer to "Locating Your

Gas fi replace" section)

b) Clearances to Combustibles (Refer to

"Clearances" section)

c) Mantle Clearances (Refer to "Mantel

Clearances" section)

d) Framing & Finishing Requirements (Refer

to "Framing & Finishing" section)

e) Venting Requirements (Refer to "Venting"

section)

2) Assemble Top and Side Standoffs (Refer to

"Unit Assembly Prior to Installation).


3) Slide unit into place.

4) Install vent (Refer to "Venting Arrangement"

sections).

5) Make gas connections (Refer to "Gas Line

Installation section).

6) Test the pilot (Refer to "Pilot Adjustment"

section).

4) This appliance is Listed for bedroom

installations when used with a listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.

5) The P33 Sunrise™ Gas Fireplace is approved

for alcove installations, see "Clearances"
section for details.

6) We recommend that you plan your installation

on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.

Note: For vent terminations refer to

"Exterior Vent Termination Locations"
section.