Installation, Regency, Direct vent flex system – Regency P33 SunriseTM P33S-LP4 User Manual

Page 15: Inst alla tion, Alternate horizontal termination caps

Advertising
background image

Regency P33 Sunrise

TM

Gas Fireplace

15

INST

ALLA

TION

Wherever necessary due to
external location of cap, the
AstroCap can be replaced with
the FPI Riser Vent Termina-
tion Cap.

REGENCY

®

DIRECT VENT FLEX SYSTEM

Horizontal Terminations Only

This venting system, in combination with the P33S-4 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock
Hersey. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .

Regency

®

Direct Vent Flex Termination Kit (Part # 946-513) includes all the parts needed to install the P33S-4 with a maximum run of 2

feet. If installing the P33S-4 with a continuous vent length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) use Kit # 946-515 (4 ft) or 946-
516 (10 ft) or see "Rigid Pipe Venting Systems" Section for alternate venting arrangements.

MINIMUM

FLEX KIT CENTER-LINE

MINIMUM

RIGID PIPE CENTER-LINE

2

0

6

4

8

2

0

6

4

8

V

ertical

Height

(Feet)

Min.

30"

(762mm)

Horizontal (Feet)

Max. 24"(0.6m)

2

0

6

4

8

2

0

6

4

8

V

ertical

Height

(Feet)

Min.

26”

(660mm)

Horizontal (Feet)

Max. 24"(0.6m)

AstroCap Flex Kits

1

6-7/8" dia. fl exible liner (kit length)

2

4" dia. fl exible liner (kit length)

3

spring spacers (3)

4

thimble (2)

5

AstroCap termination cap (1)

6

screws (12)

7

tube of Mill Pac (1)

8

plated screws (8)

Notes:
1) Liner sections should be continuous

without any joints or seams.

2) Only Flex pipe purchased from Regency

®

may be used for Flex installations.

Alternate

Horizontal

Termination

Caps

INSTALLATION