Installation, Vertical termination with co-linear flex system, Inst alla tion – Regency P33 SunriseTM P33S-LP4 User Manual

Page 20

Advertising
background image

Regency P33 Sunrise

TM

Gas Fireplace

20

INST

ALLA

TION

INSTALLATION

Flex Liner

Exhaust

Flue

A maximum

of two certified

joiner kits

may be used

per length.

#948-305

35 ft (11m)

Air Intake

Co-linear DV

Vertical Termination

Cap # 946-529

Co-Linear

Flex

Adapter

with Kit#

946-563

Outer

Pipe

with Kit#

946-563

Inner Pipe

Adapter

with Kit#

946-563

Rigid Pipe Adaptor

# 510-994

Pipe Length

45 Elbow

o

VERTICAL TERMINATION

WITH CO-LINEAR FLEX SYSTEM

This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. See the "Venting
Arrangements - Vertical Terminations" Section for
minimum and maximum heights.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical

Termination

Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter Kit

which contains the following:

Co-linear Flex Adapter

Outer

Pipe

Inner

Pipe

Adapter

510-994 Rigid

Pipe

Adaptor

46DVA-E45 45

o

Elbow

Alternate Approved Caps
46DVA-VC Vertical Termination Cap
46DVA-VCH High Wind Cap
46DVAGK 3" Co-linear Adapter with fl ashing

Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

THE APPLIANCE MUST NOT BE

CONNECTED TO A CHIMNEY FLUE

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

Advertising