Installation, Wiring diagram aeration adjustment, Inst alla tion – Regency P33 SunriseTM P33S-LP4 User Manual

Page 33

Advertising
background image

Regency P33 Sunrise

TM

Gas Fireplace

33

INST

ALLA

TION

WIRING DIAGRAM

AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.

Minimum Air Shutter Opening:

NG 1/16"
LP 1/4"

CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.

Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.

CAUTION: Carbon will be produced if air shutter

is tightly closed.

Note: Any damage due to carboning

resulting from improperly setting
the aeration controls is NOT covered
under warranty.

INSTALLATION

6”

(152mm)

Openings for

electrical connections

120 V. Power IN

Millivolt Wires

4-1/2”

(114mm)

7/16”

(11mm)

2-5/16”

(59mm)

Ground

Green

Neutral

Live

Black

Red

Red

Minimum Convection

Air Temp. Switch

Ground

ON

OFF

Rotary Speed

Control

120V AC
60 Hz

Fan

To Thermocouple IN

Pilot

Assembly

H

I

LO

OFF

ON

P

IL

O

T

Gas

Pilot

Thermopile

Thermocouple

Electrode

Lockwasher

Fan

ground wire

Nut

#8 Ground Lug

(mobile home

approved)

Star washer

Remote Transmitter

(Optional)

ON

OFF

Regency

Remote Receiver

or Thermostat

(Millivolt) (Optional)

Brown

Red

Black

White

"S.I.T" Valve

Burner ON

OFF

(To THTP)

(To TH)

Gas
In

DC Spark

Box

Ground

(To THTP)

(To TH)