Regency P33 Sunrise

TM

Gas Fireplace

24

INST

ALLA

TION

INSTALLATION

Horizontal Venting with Three (3) 90

o

Elbows

Vertical Venting with Two (2) 90

o

Elbows

Vertical Venting with Two (2) 90

o

Elbows

For additional vertical venting with
2 x 90

o

elbows, refer to "Rigid Pipe

Venting Arrangements" Section.

One 90

o

elbow = Two 45

o

elbows.

Option

V

H

V + V1

H + H1

With these options,

maximum total pipe

length is 30 feet with

minimum of 12 feet

total vertical and

maximum 9 feet total

horizontal.

P l e a s e n o t e

minimum 1 foot

between 90

o

elbows

is required.

A)

2' Min.

1' Max.

3' Min.

4' Max.

B)

3' Min.

2' Max.

4' Min.

5' Max.

C)

4' Min.

3' Max.

6' Min.

6' Max.

D)

5' Min.

4' Max.

8' Min.

7' Max.

E)

6' Min.

5' Max.

10' Min.

8' Max.

F)

7' Min.

6' Max.

12' Min.

9' Max.

One 90

o

elbow = Two 45

o

elbows.

Option

V

H

V + V1

With these options,

maximum total pipe

length is 30 feet with

minimum of 6 feet total

vertical and maximum 8

feet total horizontal.

Please note minimum

1 foot between 90

o

elbows is required.

A)

1' Min. 4' Max.

2' Min.

B)

2' Min. 5' Max.

3' Min.

C)

3' Min. 6' Max.

4' Min.

D)

4' Min. 7' Max.

5' Min.

E)

5' Min. 8' Max.

6' Min.

One 90

o

elbow = Two 45

o

elbows.

Option

H + H1

V

With these options, maximum

total pipe length is 30 feet

with minimum of 6 feet total

vertical and maximum 6 feet

total horizontal.

Please note minimum 1

foot between 90

o

elbows is

required.

A)

2' Max.

2' Min.

B)

3' Max.

3' Min.

C)

4' Max.

4' Min.

D)

5' Max.

5' Min.

E)

6' Max.

6' Min.