Installation, P q o n, Framing dimensions – Regency P33 SunriseTM P33S-LP4 User Manual
Page 12: Inst alla tion

Regency P33 Sunrise
TM
Gas Fireplace
12
INST
ALLA
TION
G
H
I
I
M
J
L
K
P Q
O
N
10" (254mm)
dia. Hole through
wall Vent.
Opening for gas
connection
Top Header
.
Wood, drywall
or other facing
J
I
Floor
INSTALLATION
Framing Dimensions
Description
P33S
G
Framing Width
33-1/4"(845mm)
H
Framing Height *
31-3/4" (806mm)
I
Framing Rise from Floor
12" (305mm) Min.
J
Framing Depth Horizontal
Vertical
19-1/2" (495mm) Vertical Rise
16-1/2" (419mm) Rigid / 12-3/4" (324mm) Flex
K
Corner Wall Length
37-1/2" (953mm)
L
Corner Facing Wall Width
53-1/4" (1353mm)
M
Framed Chase Ceiling*
36" (914mm) Rigid
32" (812mm) Flex
N
Vent Centerline Height*
30" (762mm) Rigid
26" (660mm) Flex
O
Gas Connection Height*
1 1/2" (38mm)
P
Gas Connection Inset*
4" (102mm)
Q
Gas Connection Width*
3" (76mm)
R
Minimum Framing Depth
16 1/2 (419mm) Rigid
12-3/4" (324mm) Flex
FRAMING DIMENSIONS
NOTE: If this is an outside corner, the
minimum distance between the vent
and the outside corner is 6" (15cm) with
AstroCap termination cap or 12" (30cm)
with Rigid Vent termination cap.
(For example Dura-Vent)