Installation, P q o n, Framing dimensions – Regency P33 SunriseTM P33S-LP4 User Manual

Page 12: Inst alla tion

Advertising
background image

Regency P33 Sunrise

TM

Gas Fireplace

12

INST

ALLA

TION

G

H

I

I

M

J

L

K

P Q

O

N

10" (254mm)

dia. Hole through

wall Vent.

Opening for gas

connection

Top Header

.

Wood, drywall

or other facing

J

I

Floor

INSTALLATION

Framing Dimensions

Description

P33S

G

Framing Width

33-1/4"(845mm)

H

Framing Height *

31-3/4" (806mm)

I

Framing Rise from Floor

12" (305mm) Min.

J

Framing Depth Horizontal
Vertical

19-1/2" (495mm) Vertical Rise

16-1/2" (419mm) Rigid / 12-3/4" (324mm) Flex

K

Corner Wall Length

37-1/2" (953mm)

L

Corner Facing Wall Width

53-1/4" (1353mm)

M

Framed Chase Ceiling*

36" (914mm) Rigid

32" (812mm) Flex

N

Vent Centerline Height*

30" (762mm) Rigid

26" (660mm) Flex

O

Gas Connection Height*

1 1/2" (38mm)

P

Gas Connection Inset*

4" (102mm)

Q

Gas Connection Width*

3" (76mm)

R

Minimum Framing Depth

16 1/2 (419mm) Rigid

12-3/4" (324mm) Flex

FRAMING DIMENSIONS

NOTE: If this is an outside corner, the

minimum distance between the vent
and the outside corner is 6" (15cm) with
AstroCap termination cap or 12" (30cm)
with Rigid Vent termination cap.

(For example Dura-Vent)

* Measured from base of unit.

Advertising