1 how to start and stop – Toshiba VF-S11 User Manual

Page 21

Advertising
background image

E6581160

20

3

3.1.1 How to start and stop

[Example of a EOQF setting procedure]

Key operated

LED display

Operation



Displays the operation frequency (operation stopped).
(When standard monitor display selection H= [Operation
frequency])

CWJ

Displays the first basic parameter [History (CWJ)].

EOQF

Press either the or key to select “EOQF”.



Press ENTER key to display the parameter setting. (Default setting:).



Change the parameter to  (terminal board) by pressing the key.



⇔EOQF

Press the ENTER key to save the changed parameter. EOQF and the
parameter set value are displayed alternately.

(1) Start and stop using the operation panel keys (EOQF=)

Use the

and

keys on the operation panel to start and stop the motor.

: Motor starts.

: Motor stops.

To switch between forward run and reverse run from the control panel, the parameter fr
(forward/reverse run selection) needs to be set to 2 or 3.

(2) RUN/STOP by means of an external signal to the terminal board (EOQF=):

Sink (Negative) logic

Use external signals to the inverter terminal board to start and stop the motor.

Frequency

ON
OFF

F-CC

Slow down
and stop

Short and terminals: run forward

Open and terminals: slow down and stop

CC

F

CC

(3) Coast stop

The standard default setting is for slowdown stop. To
make a coast stop, assign a "1(ST)" terminal function
to an idle terminal using the programmable terminal
function.
Change to H=.
For coast stop, open the ST-CC when stopping the
motor in the state described at left.The monitor on the
inverter at this time will display QHH.

Motor
speed

ON
OFF

ON
OFF

F-CC

ST-CC

Coast stop