Table of parameters and data, 1 user parameters, 2 basic parameters – Toshiba VF-S11 User Manual

Page 51

Advertising
background image

E6581160

50

7

7. Table of parameters and data

For details on the function of each parameter, refer to the full version of English manual (E6581158).

7.1

User parameters

Title

Function

Unit

Minimum

setting unit

Panel/Comm

unication

Adjustment range

Default setting

User

setting

Reference

E6581158

HE

Operation
frequency of
operation panel

Hz

0.1/0.01

NN

-WN

0.0

3.2

7.2

Basic parameters

• Four navigation functions

Title

Communication

No.

Function

Unit

Minimum

setting unit

Panel/Commun

ication

Adjustment range

Default

setting

User

setting

Reference

E6581158

CWJ

-

History function

-

-

Displays parameters in groups of five
in the reverse order to that in which
their settings were changed.
* (Possible to edit)

-

4.1.4

CW

0000

Automatic
acceleration/
deceleration

-

-

0: Disabled (manual)
1: Automatic
2: Automatic (only at acceleration)

0

5.1.1

CW

0001

Torque boost
setting macro
function

-

-

0: Disabled
1: Automatic torque boost + auto-

tuning

2: Vector control + auto-tuning
3: Energy saving + auto-tuning

0

5.2

CW

0040

Parameter setting
macro function

-

-

0: Disabled
1: Coast stop
2: 3-wire operation
3: External input UP/DOWN setting
4: 4-20 mA current input operation

0

5.3

• Basic parameters

Title

Communication

No.

Function

Unit

Minimum

setting unit

Panel/Commun

ication

Adjustment range

Default

setting

User

setting

Reference

E6581158

EOQF

0003

Command mode
selection

-

-

0: Terminal board
1: Operation panel

1

5.4
7.2

HOQF

0004

Frequency setting
mode selection 1

-

-

0: Built-in potentiometer
1: VIA
2: VIB
3: Operation panel
4: Serial communication
5: UP/DOWN from external contact
6: VIA + VIB (Override)

0

5.4

6.5.1

7.1

Advertising