Toshiba VF-S11 User Manual

Page 34

Advertising
background image

E6581160

33

4

Key operated

LED display

Operation

W

Press the ENTER key to enable the user parameter automatic edit
function.

or

WH

(WT)

CEE

Searches for parameters that are different in value from the standard
default setting and displays those parameters. Press the ENTER key
or the key to change the parameter displayed. (Pressing the key
moves the search in the reverse direction).



Press the ENTER key to display the set value.



Press the key and key to change set value.



⇔CEE

Press the ENTER key to save the changed value. The parameter
name and the programmed value will flash on and off alternately.
After the change has been saved, “W“ is displayed.

WH

(WT)

Use the same steps as those given above to display parameters that
you want to search for or change setting with the key and key.

ITW

When IT. W appears again, the search is ended.

ITW

HTH



A search can be canceled by pressing the MODE key. Press the
MODE key once while the search is underway to return to the display
of parameter setting mode.
After that you can press the MODE key to return to the status
monitor mode or the standard monitor mode (display of operation
frequency).

If there is anything you do not understand during this operation, press the key several times to
start over from the step of auh display.

4.2.4 Searching for a history of changes, using the history

function (CWJ)

History function (CWJ):
Automatically searches for 5 latest parameters that are programmed with values different from the
standard default setting and displays them in the CWJ. Parameter setting can also be changed
within this group CWJ.

Notes on operation
• If no history information is stored, this parameter is skipped and the next parameter “CWK” is

displayed.

• JGCF and GPF are added respectively to the first and last parameters in a history of changes.

MODE

MODE

MODE