Qtable of output terminal functions 2 – Toshiba VF-S11 User Manual

Page 69

Advertising
background image

E6581160

68

7

Q

Table of output terminal functions 2

Function

No.

Code

Function

Action

12

OT

Over-torque detection

ON: Torque current is equal to or larger than

H

set value and longer than H

set time.

OFF: The torque current is equal to or less than

(H set value - H set value).

13

OTN

Inversion of over-torque detection

Inversion of OT

14

RUN

Start/Stop

ON: When operation frequency is output or during

(FD)

OFF: Operation stopped

15

RUNN

Inversion of RUN/STOP

Inversion of RUN setting

16

POL

OL pre-alarm

ON: 50% or more of calculated value of overload

protection level

OFF: Less than 50% of calculated value of

overload protection level

17

POLN

Inversion of OL pre-alarm

Inversion of POL setting

18

POHR

Braking resistor overload pre-alarm

ON: 50% or more of calculated value of H

set overload protection level

OFF: Less than 50% of calculated value of

H

set overload protection level

19

POHRN

Inversion of braking resistor overload pre-alarm

Inversion of RCHR setting

20

POT

Over-torque detection pre-alarm

ON: Torque current is equal to or larger than 70%

of H set value.

OFF: The torque current is below (H set

value x 70% - H set value).

21

POTN

Inversion of over-torque detection pre-alarm

Inversion of POT setting

22

PAL

Pre-alarm

One of the following is turned on:

ON POL, POHR, POT, MOFF, UC, OT, LL
stop, COT, and momentary power failure
slowdown stop.

or E,R,QTJ issues an alarm

All the following are turned off:

OFF POL, POHR, POT, MOFF, UC, OT, LL
stop, COT, and momentary power failure
slowdown stop.

or E,R,QTJ issues no alarm

23

PALN

Inversion of pre-alarm

Inversion of PAL setting

24

UC

Small-current detection

ON: The output current is equal to or less than

H

set value for H set time.

OFF: The output current is equal to or larger than

H

set value + 10%.

25

UCN

Inversion of small-current detection

Inversion of UC setting

26

HFL

Significant failure

ON: QEC,QEN,QV,G,

GGR

,GVP,GRJQ,GTT-



,QJ,WR,GH,WE,

GV[R

,QTGRJ)

OFF: Failure other than the above

27

HFLN

Inversion of significant failure

Inversion of HFL setting

28

LFL

Insignificant failure

ON: (QE-,QR-,QJ,

QN

-,QNT)

OFF: Failure other than the above

29

LFLN

Inversion of insignificant failure

Inversion of LFL setting

30

RDY1

Ready for operation (including ST/RUN)

ON: Ready for operation (ST and RUN are also

ON)

OFF: Others

31

RDY1N

Inversion of ready for operation (including
ST/RUN)

Inversion of RDY1 setting

32

RDY2

Ready for operation (excluding ST/RUN)

ON: Ready for operation (ST and RUN are not

ON)

OFF: Others

33

RDY2N

Inversion of ready for operation (excluding ST/RUN)

Inversion of RDY2

34

FCVIB

Frequency VIB selection

ON: VIB selected as frequency command
OFF: Terminal other than VIB selected as

frequency command

Advertising