1 how to set the basic parameters – Toshiba VF-S11 User Manual

Page 31

Advertising
background image

E6581160

30

4

4.2.1 How to set the basic parameters

All of the basic parameters can be set by the same step procedures.

Switches to the setting monitor mode.

* Parameters were

factory-set by default
before shipment.

* Select the parameter to

be changed from "Table
of parameters".

* If there is something

that you do not
understand during the
operation, press the
MODE key to return to
the  indication.

* See 7.2 for basic

parameters.

Reads the programmed parameter
setting.

Saves the changed value of the
parameter setting.

Selects parameter to be changed.

Changes the parameter setting.

[Steps in key entry for basic parameters]

MODE

Steps in setting are as follows (example of changing the maximum frequency from 80Hz to 60Hz).

Key operated

LED display

Operation



Displays the operation frequency (operation stopped).
(When standard monitor display selection H= [Operation
frequency])

CWJ

The first basic parameter “CWJ” (history function) is displayed.

HJ

Press either the or key to select “HJ”.



Pressing the ENTER key reads the maximum frequency.



Press the key to change the maximum frequency to 60Hz.



⇔HJ

Press the ENT key to save the maximum frequency. HJ and the
frequency are displayed alternately.

After this,

→Displays the same

programmed
parameter.

→Switches to the

display in the
status monitor
mode.

→Displays names

of other
parameters.

MODE

MODE

Advertising