Toshiba VF-S11 User Manual

Page 42

Advertising
background image

E6581160

41

5

(Continued)

Item displayed

Key

operated

LED

display

Communic
ation No.

Description

Input terminal

}}}ii}ii

FE06

The ON/OFF statuses of the control input
terminals (F, R, RES, S1, S2, S3, VIB and VIA) are
displayed in bits.

ON: 
OFF: _

Output terminal

0

}ii

FE07

The ON/OFF status of each of the control signal
output terminals (RY, OUT and FL) at the
occurrence of a trip is displayed in bits.

ON: 
OFF: _

CPU1 version

X

FE08

The version of the CPU1 is displayed.

CPU2 version

XY

FE73

The version of the CPU2 is displayed.

Memory version

XG

FE09

The version of the memory mounted is displayed.

PID feedback

F

FE22

The PID feedback value at the occurrence of a trip
is displayed. (Hz / free unit)

Frequency
command value
(PID-computed)

D

FE15

The PID-computed frequency command value at
the occurrence of a trip is displayed. (Hz / free
unit)

Integral input
power

k

FE76

The integrated amount of power (kWh) supplied to
the inverter is displayed.
(0.01=1kWh, 1.00=100kWh)

Integral output
power

J

FE77

The integrated amount of power (kWh) supplied
from the inverter is displayed.
(0.01=1kWh, 1.00=100kWh)

Rated current

C

FE70

The inverter rated current (A) at the occurrence of
a trip is displayed.

Past trip 1

QR

⇔

FE10

Past trip 1 (displayed alternately)

Past trip 2

QJ

⇔

FE11

Past trip 2 (displayed alternately)

Past trip 3

QR

⇔

FE12

Past trip 3 (displayed alternately)

Past trip 4

PGTT

⇔

FE13

Past trip 4 (displayed alternately)

(Continued overleaf)

0

}ii

RY-RC

FL

OUT-NO

}}}ii}ii

VIA

VIB

S3

S2

RES

S1

R

F

Note 4

Note 5

Note 7

Note 7

Note 7

Note 7

Advertising