power classification function.

Power Limit by Management: Tick this check box to enable/disable the port

power limit management for PoE power management.

Detect Legacy Signature: By default, the PoE switch only provides power to

the connected PD which follows the IEEE 802.3af standard. Having ticked

this check box, the legacy detection is to identify the PD (not in compliance

with the IEEE 802.3af standard) their unique electrical signatures in order for

the PoE switch can provide the power to the PD.

Priority: Set port priority for the PoE power management. 1 = C (critical), 2 =

H (High), 3 = L (Low).

Power Limit Max (mW) (<15400): Set the power limit value. The maximum

value must less 15400mW.

Fault Status: The PD error status message.

Null: It means no PD is connected or the connected PD status is normal.

Overload: It means the current is over the PD current classification

limited (475mA @ 48V DC) over 50ms.

Mode Status: The PD current operation mode status.

V sample or I sample: It means Current sample or Voltage sample.

When PD is detected and current is supplied, the PoE switch will keep

detecting and sampling some current or voltage to ensure whether the

PD is still active on the port. It is an IEEE 802.3af operating procedure.

R detect: When the port doesn’t connect with any PD, the PoE switch

will poll each port and detects the resistor.

Discovery R (ohms): Displays the resistance value.

Port Current (mA): Displays the current value.

Port Voltage (V): Displays the voltage value.

Port Power (W): Displays the watt value.

Class Current (mA): Displays current class. When the Bypass classification

is enabled, the class value will not show in here.

Determined Class: Displays power class. When the Bypass classification is

enabled, the class value will not show in here.