Operating the Equipment Locally

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

Page 4-69

ST.TM.E10076.3

Bit-rate Option

To access the Bit-rate option, press the Bit-rate softkey in the
Data B - RS422

Menu. This enables the bit-rate of the RS-422

synchronous data channel to be set.

Table 4.70: Bit-rate Options

Selected Option

Description

Settings cycle from 56 to 1792 in steps of 56 then from 64 to
2048 in steps of 64, then back to 56

RS-422 synchronous data
channel bit-rate.

RS422 PID Option

The RS422 PID option is selected from the Data B - RS422 Menu by

pressing the RS422 PID softkey. The option is used for entering or

updating data PIDs. Enter a PID using the softkeys, then press the Enter

softkey to accept it
To be DVB compliant, PIDs below 32 are reserved. Therefore PIDs 32 to

8191 are available for use. In the event of a clash, one of the PIDs will be

changed by the Encoder’s internal checking algorithm.

Test Mode Option

The Test Mode option is selected from the Data B - RS422 Menu by

pressing the Test Mode softkey. The option is used for turning the test

mode On and Off.

Delay Option

The Delay option is selected from the Data A - RS232 Menu by pressing

the Delay softkey. The option cannot be changed.

D Mode Option

The D Mode option is selected from the Data A - RS232 Menu by pressing

the D Mode softkey. The option cannot be changed.

SNMP oid index Option

The SNMP oid

9

index option is selected from the Data B - RS422 Menu by

pressing the SNMP oid index softkey. See SNMP oid index Option on

page 4-68 for details of this option.

Version Option

This option indicates the version of the data. It is for status only and

cannot be changed.

9

oid = object identifier.