Installing the Equipment

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

Page 2-7

ST.TM.E10076.3

2.4

AC Mains Operating Voltage and Earthing

2.4.1

AC Power Supply

CAUTION...

This product should be operated only from the type of power source indicated on the marking label. If

you are not sure of the type of power supply to your business, consult a qualified electrical engineer or

your local power company.

See Annex B, Technical Specification for a full power supply specification.

There are no links or switches to be altered for operation from different ac

supplies.

2.4.2

Power Cable and Earthing

General

Check that the ac power cable is suitable for the country in which the

Encoder is to be used.

WARNINGS...

1.

IF THE MOULDED PLUG FITTED TO THE MAINS CABLE SUPPLIED WITH THIS UNIT IS NOT

REQUIRED, PLEASE DISPOSE OF IT SAFELY. FAILURE TO DO THIS MAY ENDANGER LIFE

AS LIVE ENDS MAY BE EXPOSED IF THE REMOVED PLUG IS INSERTED INTO A MAINS

OUTLET.

2.

POWER-SUPPLY CORDS SHOULD BE ROUTED SO THAT THEY ARE NOT LIKELY TO BE

WALKED ON OR PINCHED BY ITEMS PLACED UPON OR AGAINST THEM, PAYING

PARTICULAR ATTENTION TO CORDS AT PLUGS, CONVENIENCE RECEPTACLES, AND

THE POINT WHERE THEY EXIT FROM THE APPLIANCE.

The unit is supplied with three, detachable mains-supply cables fitted with

moulded plugs suitable for the USA, UK or Europe.
The wires in the mains cable are coloured in accordance with the wire

colour code shown in Table 2.1.

Table 2.1: Supply Cable Wiring Colours

UK
(BS 1363)

EUROPE
(CEE 7/7)

USA
(NEMA 5-15P)

Earth:

Green-and-yellow

Green-and-yellow

Green

Neutral:

Blue

Blue

White

Live:

Brown

Brown

Black

Protective Earth/Technical Earth

WARNINGS...

1.

THIS UNIT MUST BE CORRECTLY EARTHED THROUGH THE MOULDED PLUG SUPPLIED.

IF THE LOCAL MAINS SUPPLY DOES NOT HAVE AN EARTH CONDUCTOR DO NOT

CONNECT THE UNIT. CONTACT CUSTOMER SERVICES FOR ADVICE.

2.

BEFORE CONNECTING THE UNIT TO THE SUPPLY, CHECK THE SUPPLY REQUIREMENTS

IN ANNEX B.