Technical Specification

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

Page B-13

ST.TM.E10076.3

B.4

Control and Monitoring

B.4.1

Remote Control - Ethernet 1 and 2

Table B.21: Ethernet Specification

Item

Specification

Safety status

SELV

Connector designation

ETHERNET#1 and ETHERNET#2

Connector type

8-way RJ-45 socket, 10BaseT (ISO 882/3)

B.4.2

Local Control

Local control is by means of the front panel keypad and LCD display.

B.4.3

Alarm

Table B.22: Alarm Specification

Item

Specification

Safety status

SELV

Connector designation

ALARM

Connector type

9-way D-type male

Alarm contacts

Change-over contacts (5

W in common)

Fail contacts

Change-over contacts (5

W in common)

Reset contacts

Short pins 9 and 5 (resets the Encoder)

Relay Contact Rating

Maximum switching power

30 W

Maximum switching voltage

110 V

Maximum switching current

1 A

B.4.4

Remote Control

This connector provides an RS-232/RS-485 user interface control port that

allows the unit to be controlled by an external master.

Table B.23: Remote Control Specification

Item

Specification

Safety status

SELV

Connector designation

REMOTE CONTROL

Connector type

9-way D-type male

B.4.5

RS-232 Data (Asynchronous)

RS-232 is not currently supported on the Base Board in Build version 2.0.0

but it is in the option module M2/EOM2/DAT.