Bit-rate (188) and bit-rate (204) option, Clock, Pcr pid option – TANDBERG E5714 User Manual

Page 171: 7 clock, 8 pcr pid option

Advertising
background image

Operating the Equipment Locally

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

Page 4-93

ST.TM.E10076.3

4.12.6 Bit-rate (188) and Bit-rate (204) Option

NOTE…
If the Packet Length option is set to 188 bytes then only the Bit-rate (188) option is displayed. If the

Packet Length option is set to 204 bytes then both the Bit-rate (188) and Bit-rate (204) options are

displayed.

To access the either of the bit-rates, press the Bit-rate (188) or the

Bit-rate (204) softkey in the Mux Menu.
Both the Bit-rate (188) and the Bit-rate (204) can be in the range of

0 Mbit/s to 50 Mbit/s.

Table 4.113: Bit-rate (188) and Bit-rate (204) Options

Selected Option

Description

188 / 204
Min:

0.0000 Mbit/s

Max (without Remux):110.0000 Mbit/s
Max (with Remux): 50.0000 Mbit/s
Step Size:

0.0001 Mbit/s

Multiplexer output bit-rate when in baseband output
format and ASI output mode.
Changing the bit-rate affects the automatic video bit-
rate and video resolution calculations.

If the specified bit-rate is outside the valid input range, a confirmation

screen is displayed which shows the maximum/minimum value allowed.

4.12.7 Clock

NOTE…
This option indicates the origin of the clock. Prior to Build Version 3.0.0 it was set to Local Oscillator

and could not be changed. After Build Version 3.0.0 it must be set to a video or external source before

attempting to change the clock value or it will default to Local Oscillator.

To access the Clock option, press the Clock softkey in the Mux Menu.

Table 4.114: Clock Options

Selected Option

Description

Local Oscillator

The system clock is derived from the local oscillator.

HSYNC (External)

The system clock is locked to the HSYNC input.

Video

The system clock is locked to the video source.

4.12.8 PCR PID Option

To access the PCR PID option, press the PCR PID softkey in the Mux Menu.

This shows the Program Clock Reference Packet Identifier.

Table 4.115: PCR PID Options

Selected Option

Description

Min:

1

Max:

8190 (1FFEh)

Step Size:

1

Advertising