Video encoder related errors, Audio related errors, H.8 video encoder related errors – TANDBERG E5714 User Manual

Page 309: H.9 audio related errors

Advertising
background image

Error Messages

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

Page H-7

ST.TM.E10076.3

H.8

Video Encoder Related Errors

Table H.6: Video Encoder Error Messages

Error Message

Action to Take

Comms Error

Config Update

VCM Stopped

Power Encoder off, then check that the Base Board is firmly seated in the
chassis. Do this by firmly pressing it from the rear of the Encoder into the chassis.
Power on the Encoder. If the fault persists call Service Engineer.

Bad Parameters

Duplicate PID

Invalid PID

VBI, Bit-rate too low

VBI Hor Res too low

Mux Bit-rate too low

Check the Encoder configuration.

No interrupt

DSP Overrun

Boot Fail

Bad Frame Rate

Rate Buffer OF/UF

DSP Health

Bad Filter Coeffs

Repeated PCR Resync

Coding Mode Error

PCR Error

No PowerUp Tests

Power Encoder off, then check that the Base Board is firmly seated in the
chassis. Do this by firmly pressing it from the rear of the Encoder into the chassis.
Power on the Encoder. If the fault persists call Service Engineer.

No Reflex Messages

Check Ethernet connection to Encoder.

H.9

Audio Related Errors

Table H.7: Audio Error Messages

Error Message

Action to Take

Module Fault

Comms Error

Config Update

Processor Stopped

Power Encoder off, then check that the Base Board and any audio modules are
firmly seated in the chassis. Do this by firmly pressing them from the rear of the
Encoder into the chassis. Power on the Encoder. If the fault persists call Service
Engineer.

Incorrect parameters

Check the parameter settings for the reported audio channel.

PCR Error

Power Encoder off, then check that the Base Board and any audio modules are
firmly seated in the chassis. Do this by firmly pressing them from the rear of the
Encoder into the chassis. Power on the Encoder. If the fault persists call Service
Engineer.

Silence Timeout Left

Silence Timeout Right

A silence timeout period can be set (contact Customer Services for details). The
error message is generated if the audio is silent for greater than the timeout
period. The default timeout period is 0 which disables this feature, and so the
error should not be reported.

Advertising