1-2. Outdoor Unit

Note 1 : The sound level is measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in

the actual operating environment become larger than the indicated values due to the effects of external sound.

Note 2 : Rated conditions

Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

Model name

Appearance

Power supply

Type

Compressor

Motor

(kW)

Pole

Refrigerant charged

(kg)

Refrigerant control

Standard length

Max. total length

(m)

Pipe

Over 20m

Height difference

Outdoor lower

(m)

Outdoor higher

(m)

Outer

Height

(mm)

Width

(mm)

dimension

Depth

(mm)

Total weight

(kg)

Heat exchanger

Fan

Fan unit

Standard air flow High

(m³/h)

Motor

(W)

Connecting

Gas side

(mm)

pipe

Liquid side

(mm)

Protection device

Sound level

High (Mid./Low)

(dB•A)

(Note 2)

(Cooling/Heating)

RAV-SM560AT-E

RAV-SM800AT-E

Silky shade (Muncel 1Y8.5/0.5)

1 phase 230V (220 – 240V) 50Hz

(Power exclusive to outdoor is required.)

Hermetic compressor

1.1

1.6

4 poles

R410A 0.9

R410A 1.5

Pulse motor valve

20 (without additional charge)

30

50

Add 20g/m (Max. 200g)

Add 40g/m (Max. 1200g)

15

30

595

795

780

780

270

270

35

55

Finned tube

Propeller fan

2400

3400

43

63

Ш12.7 (1/2”)

Ш15.9 (5/8”)

Ш6.4 (1/4”)

Ш9.5 (3/8”)

Discharge temp. sensor

Over-current sensor

Compressor thermo.

46/48

48/50

– 3 –