Toshiba RAV-SM800XT-E User Manual

Page 54

Advertising
background image

– 52 –

[14 error]

[16 error]

Check rare short of compressor trouble.
Defect Replace

Check IPDU.
Defect Replace

NO

NO

NO

YES

YES

NO

YES

NO

YES

YES

NO

YES

Replace IPDU.

Replace IPDU.

Is compressor normal?

Improve the power supply line.

* For RAV-SM560AT-E,

check RY01 on the control P.C. board.

* Replace control P.C. board

of RAV-SM560AT-E.

* Single-phase type is not

provided to RAV-SM560AT-E.

* Replace control P.C. board

of RAV-SM560AT-E.

Is power voltage normal?

Is not AC fuse fused?

Check and correct circuit cables.
Correct connection of connector.
Check and correct reactor connection.

Are connections of

cabling/connector normal?

Does RY01 relay of

IPDU operate?

Is not 14 errors output

when an operation is performed by

removing 3P connector of compressor?

Compressor error Replace

Compressor error Replace

Check IPDU P.C. board
Defect Replace

Are connections of

cable/connector normal?

Check and correct circuit cabling
such as cabling to compressor.

NO

YES

NO

YES

YES

Is not winding shorted?

(Is resistance between windings 0.6 to 1.2

?)

Is compressor normal?

Is not earthed?

Is not winding opened?

YES

YES

NO

NO

NO

Compressor error Replace