11-3. Outdoor Unit (RAV-SM800AT-E)

No.



Part name

Common
procedure

Procedure

CAUTION

Never forget to put on the gloves at
working time, otherwise an injury will be
caused by the parts, etc.

1. Detachment
1) Stop operation of the air conditioner, and

also turn off switch of the breaker.

2) Remove the front panel.

(ST1T Ø4 x 10L, 3 pcs.)

• After taking off screws, remove the front

panel by pulling it downward.

3) Disconnect the connecting cables and

power cord from the terminals and cord
clamp.

4) Remove the upper cabinet.

(ST1T Ø4 x 10L, 6 pcs.)

2. Attachment
1) Attach the waterproof cover.

CAUTION

Be sure to attach a waterproof cover.
If it is not attached, there is a possibility
that water enters inside of the outdoor unit.

2) Attach the upper cabinet.

(ST1T Ø4 x 10L, 6 pcs.)

3) Connect the connecting cable and power

cord at the terminal and fix them with cord
clamp.

CAUTION

Using bundling band sold at a market, be
sure to fix the power cables and indoor/
outdoor connecting cables along the inter-
unit cable so that they do not come to
contact with the compressor, valves and
cables at gas side, and the discharge pipe.

4) Attach the front cabinet.

(ST1T Ø4 x 10L, 3 pcs.)

Remarks

Front
cabinet

Upper plate
of cabinet

Water-proof
cove

– 72 –