Toshiba RAV-SM800XT-E User Manual

Page 73

Advertising
background image

No.

‰

Part name

Pulse Modulating
Valve (PMV) coil

Procedure

1. Detachment
1) Perform works of items



and

‚

.

2) Release the coil from the concavity by

turning it, and remove coil from the
PMV.

2. Attachment
1) Put the coil deep into the bottom

position.

2) Fix the coil firmly by turning it to the

concavity.

Remarks

Š

Fan guard

1. Detachment
1) Perform works of items 1 of



, and

‚

.

2) Remove the front cabinet, and put it

down so that fan guard side directs
downward.

CAUTION

Perform works on a corrugated card-
board, cloth, etc. to prevent flaw on the
product.

3) Remove the hooking claws by pushing

with minus screwdriver along with the
arrow mark in the right figure, and
remove the fan guard.

2. Attachment
1) Insert claws of the fan guard in the hole

of the front cabinet. Push the hooking
claws (10 positions) with hands and
then fix the claws.

CAUTION

All the attaching works have completed.
Check that all the hooking claws are
fixed to the specified positions.

Positioning extrusion

PMV body

Concavity

PMV coil

Minus screwdriver

Front cabinet

Hooking claw

Front cabinet

Fan guard

– 71 –

Advertising