UNIREX Pump User Manual

Page 25

Advertising
background image

MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06

Page 25 of 68

flowserve.com

Figure 4-12: Baseplate correction factors

Base type

Grouted

Bolted

Stilt mounted

Type A

1.0

0.7

0.65

Type B - Polybase

1.0

n/a

0.95

Type C

n/a

1.0

1.0

Type D

1.0

0.8

0.75

Type E - PIP

1.0

0.95

n/a

Polyshield - baseplate/

foundation

1.0

n/a

n/a

Figure 4-13: Coordinate system

Figure 4-14: Acceptance criteria equations

Set

Equations

Figure

Remarks

1

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

,

0

.

1

_

_

_

_

_

_

_

_

_

_

_

_

adj

zd

zd

adj

yd

yd

adj

xd

xd

adj

zd

zd

adj

yd

yd

adj

xd

xd

adj

zs

zs

adj

ys

ys

adj

xs

xs

adj

zs

zs

adj

ys

ys

adj

xs

xs

M

M

M

M

M

M

F

F

F

F

F

F

M

M

M

M

M

M

F

F

F

F

F

F

Adjusted

4-15

Maximum

individual

loading

2

0

.

2

_

_

_

_

_

_

_

_

_

_

_

_

+

+

+

+

+

+

+

+

+

+

+

adj

zd

zd

adj

yd

yd

adj

xd

xd

adj

zd

zd

adj

yd

yd

adj

xd

xd

adj

zs

zs

adj

ys

ys

adj

xs

xs

adj

zs

zs

adj

ys

ys

adj

xs

xs

M

M

M

M

M

M

F

F

F

F

F

F

M

M

M

M

M

M

F

F

F

F

F

F

Adjusted

4-16

Nozzle

stress, bolt

stress, pump

slippage

3

adj

zd

zd

adj

yd

yd

adj

xd

xd

adj

yd

yd

adj

zs

zs

adj

ys

ys

adj

xs

xs

adj

ys

ys

M

M

M

M

M

M

F

F

M

M

M

M

M

M

F

F

A

_

_

_

_

_

_

_

_

+

+

+

+

+

+

+

=

0

.

1

0

.

1

A

Adjusted

4-17

y-axis

movement

4

adj

zd

zd

adj

yd

yd

adj

xd

xd

adj

zd

zd

adj

yd

yd

adj

xd

xd

adj

zs

zs

adj

ys

ys

adj

xs

xs

adj

zs

zs

adj

xs

xs

M

M

M

M

M

M

F

F

F

F

F

F

M

M

M

M

M

M

F

F

F

F

B

_

_

_

_

_

_

_

_

_

_

_

+

+

+

+

+

+

+

+

+

+

=

0

.

1

0

.

1

B

Adjusted

4-18

z-axis

movement

5

0

.

1

2

2

+ B

A

-

Combined

axis

movement

Note: All of the above equations are found by dividing the applied piping loads by the adjusted figure values

.