i) Reinstall the repeller cover, repeller, rear cover,

and impeller as instructed in section 6.9.3.

j) The Checkmatic gland must now be moved forward

toward the impeller, pushing the forward lip ahead

of it. It is important that the forward lip be firmly

loaded against the seat when the gland is seated.

Care must be taken to maintain even pressure on

both sides of the gland, keeping the lip seal/ceramic

seal faces perpendicular to the shaft.

k) Tighten the gland nuts evenly.

l) Finally, the rear lip must be slipped forward and

tight against the seat. Care should be taken so

as not to damage the seal face.

6.9.2.5 Reassembly - Sealmatic with dry running

seal

Component seals will generally require that the wet end

is assembled as described in 6.9.3 so that the impeller

may be set prior to seal installation. Review the seal

assembly instructions and drawings provided by the

seal manufacturer. Section 6.9.2.2 contains the general

assembly sequences for component seals.

6.9.2.6 Reassembly - Sealmatic with FXP seal

a) Remove any sharpness of edge at wet end of

shaft with #400 emery cloth.

b) Clean all exposed surfaces of the wet end of the

shaft.

c) Install a shaft guide tool from the Flowserve tool

kit. (See figure 6-1.)

d) Insert the O-rings into the grooves on the inside

diameter of the seal rotor.

e) Slide the drive collar onto the shaft until it

contacts the bearing housing (pins facing away

from bearing housing).

f) Lubricate the O-rings and shaft with non-abrasive

liquid hand soap and slide the seal rotor onto the

shaft until it contacts the rotor drive collar. The

notches on the back side of the rotor should face

toward the bearing housing.

g) Place repeller cover face down on workbench

and set the Teflon disk against the gland surface

(i.e. end of stuffing box). Attach gland to repeller

cover and screw on gland nuts finger-tight.

h) Reinstall the repeller cover, repeller, rear cover,

and impeller as instructed in section 6.9.3.

i) Tighten gland nuts fully. Slide the seal rotor

forward until it contacts the Teflon disk. Slide the

drive collar forward until its pins are fully engaged

in the slots on the back side of the seal rotor.

j) Preload the seal by applying even pressure on

the back of the drive collar in order to push it and

the seal rotor into the Teflon disk. The rotor and

drive collar should be moved approximately 3mm

(

LQ LQWR WKH 7HIORQ GLVN 7LJKWHQ WKH GULYH

collar setscrews while maintaining pressure on

the back of the drive collar.

k) Once the pump is flooded, check the seal to ensure

it is not leaking. If the seal leaks, repeat step j)

above, applying only enough pressure to the drive

collar to stop the leak. Do not over tighten the seal.

6.9.3 Sealmatic pump: installation of repeller

cover, repeller, cover, and impeller

Group 2 pumps - see figure in section 8-3.

Group 3 pumps - see figure 6-29.

a) For Group 2 pumps, install the repeller cover to

the adapter using capscrews [6570.2].

For Group 3 pumps install the repeller cover

[1220.1] over the shaft and push it all the way

back until it touches the bearing housing.

b) Install a new repeller O-ring [4610.11] into the

repeller groove. Lubricate the O-ring with liquid

soap.

c) Install the slip-on repeller [2200.1] onto the shaft.

d) Install the repeller cover/cover gasket [4590.9].

e) For Group 2 pumps, install the cover [1220] to

the repeller cover using capscrews [6570.13].

For Group 3 pumps, install the cover [1220] to

the adapter. Attach to the adapter using

capscrews [6570.2]. Attach the repeller cover to

the cover using the capscrews [6570.13].

f) The repeller and impeller may now be set following

the instructions given in section 6.6.3.

4610.11

4590.9

6570.13

Figure 6-29 - Group 3 Sealmatic

Item

Part name

4610.11

Repeller O-ring

4590.9

Gasket – repeller cover

6570.13

Capscrew