4.6.4.2c Pump stand limitations

In cases where the pump is rigidly mounted by the

pump stand, both the casing limitations and the pump

stand limitations must be satisfied. Due to the limited

load capacity of the pump stands, it may be

necessary to restrain the piping to prevent loads.

a) Ensure all applied loads are within the allowable

limits of the casing.

b) Translate the flange loads using the formulae

found in figure 4-21. Dimensional variables S

RS

,

S

RD

and R

S

can be found in figure 4-20.

c) Calculate F

T

and F

N

using the formulae found in

figure 4-21.

d) F

T

and F

N

must be less than F

TMAX

and F

NMAX

found in figure 4-22.

e) F

T

and F

N

must meet the combination formulae

found in figure 4-22.

Figure 4-20: Dimensional data and casing limitations

Allowable casing loads (suction or discharge)

Dimensions

m (ft)

Forces N (lbf)

Moments Nm (lbf•ft)

SD

SRd

SRs

Rs

Fx

Fy

Fz

Mx

My

Mz

2x1.5V-6

0.381

(1.25)

0.191

(0.625)

0.191

(0.625)

0.163

(0.53)

1 824

(410)

17 685

(3 976)

1 824

(410)

692

(510)

976

(720)

692

(510)

2x1.5V-8

0.432

(1.42)

0.229

(0.75)

0.203

(0.67)

0.163

(0.53)

1 601

(360)

17 685

(3 976)

1 601

(360)

692

(510)

976

(720)

692

(510)

3x2V-7

0.432

(1.42)

0.203

(0.67)

0.229

(0.75)

0.163

(0.53)

2 824

(635)

28 147

(6 328)

2 824

(635)

1 120

(900)

1 722

(1 270)

1 120

(900)

3x1.5V-8

0.483

(1.58)

0.226

(0.74)

0.254

(0.83)

0.163

(0.53)

1 601

(360)

17 685

(3 976)

1 601

(360)

692

(510)

976

(720)

692

(510)

2x1.5V-10A

0.483

(1.58)

0.229

(0.75)

0.254

(0.83)

0.197

(0.65)

1 423

(320)

17 685

(3 976)

1 423

(320)

692

(510)

976

(720)

692

(510)

3x2V-10

0.508

(1.67)

0.241

(0.79)

0.267

(0.88)

0.197

(0.65)

2 402

(540)

28 147

(6 328)

2 402

(540)

1 120

(900)

1 722

(1 270)

1 120

(900)

4x3V-10

0.635

(2.08)

0.292

(0.96)

0.343

(1.13)

0.197

(0.65)

2 823

(638)

28 147

(6 328)

2 823

(638)

1 803

(1 330)

2 549

(1 880)

1 803

(1 330)

3x1.5V-13

0.61

(2.00)

0.292

(0.96)

0.318

(1.04)

0.248

(0.81)

1 134

(255)

17 685

(3 976)

1 134

(255)

692

(510)

976

(720)

692

(510)

3x2V-13

0.61

(2.00)

0.292

(0.96)

0.318

(1.04)

0.248

(0.81)

2 002

(450)

28 147

(6 328)

2 002

(450)

1 120

(900)

1 722

(1 270)

1 120

(900)

4x3V-13

0.711

(2.33)

0.33

(1.08)

0.381

(1.25)

0.248

(0.81)

2 535

(570)

28 147

(6 328)

2 535

(570)

1 803

(1 330)

2 549

(1 880)

1 803

(1 330)

6x4V-13

0.762

(2.50)

0.356

(1.17)

0.406

(1.33)

0.248

(0.81)

2 891

(650)

83 195

(18 704)

2 891

(650)

2 210

(1 630)

3 119

(2 300)

2 210

(1 630)

Figure 4-21: Pump stand load translation formulae

Forces

Moments

F

XC

= F

XS

+ F

XD

M

XC

= M

XS

+ M

XD

+ (F

ZS

× SR

S

) - (F

ZD

× SR

D

)

F

YC

= F

YS

+ F

YD

M

YC

= M

YS

+ M

YD

F

ZC

= F

ZS

+ F

ZD

M

ZC

= M

ZS

+ M

ZD

- (F

XS

× SR

S

) + (F

XD

× SR

D

)

TMax

s

zc

yc

s

zc

xc

T

F

R

M

F

R

M

F

F





Ч

+

+





Ч

+

=

2

2

707

.

0

707

.

0

MAX

N

s

yc

xc

zc

N

F

R

M

M

F

F

_

707

.

0

+

+

=

Advertising